Product Name: PCT Reactor Surfactant 700
Page: 1 of 5
This version issued: October, 2021
SAFETY DATA SHEET
Issued by: PCT Holdings Pty Ltd Phone:  (all hours)
Poisons Information Centre: 13 1126 from anywhere in Australia, (0800 764 766 in New Zealand)

Section 1 - Identification of The Material and Supplier
PCT Holdings Pty Ltd Phone:  (all hours)
1/74 Murdoch Circuit
Chemical nature: Blend of Propionic acid, Soyal Phospholipids and surfactants.
Trade Name: PCT Reactor Surfactant 700
Product Use: Acidifying and penetrating surfactant. Reduces alkaline hydrolysis of Dimethoate.
Assists with uptake of foliar fertilizers and assists in management of spray droplet
size. Reduces brown out time for Gylphosate.
Creation Date: June, 2016
This version issued: October, 2021 and is valid for 5 years from this date.
Poisons Information Centre: Phone 13 1126 from anywhere in Australia

Section 2 - Hazards Identification
Statement of Hazardous Nature
This product is classified as: Hazardous according to the criteria of SWA.
Not a Dangerous Good according to Australian Dangerous Goods (ADG) Code, IATA or IMDG/IMSBC criteria.
SUSMP Classification: S5
ADG Classification: None allocated. Not a Dangerous Good according to Australian Dangerous Goods (ADG)
Code, IATA or IMDG/IMSBC criteria.
UN Number: None allocated
GHS Signal word: WARNING
Serious eye irritation Category 2A
HAZARD STATEMENT:
H319: Causes serious eye irritation.
PREVENTION
P102: Keep out of reach of children.
P260: Do not breathe fumes, mists, vapours or spray.
P262: Do not get in eyes, on skin, or on clothing.
P264: Wash contacted areas thoroughly after handling.
P280: Wear protective gloves, protective clothing and eye or face protection.
RESPONSE
P310: Immediately call a POISON CENTRE or doctor/physician.
P363: Wash contaminated clothing before reuse.
P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P303+P361+P353: IF ON SKIN (or hair): Remove immediately all contaminated clothing. Rinse skin with water.
P304+P340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if
present and easy to do. Continue rinsing.
P370+P378: Not combustible. Use extinguishing media suited to burning materials.
STORAGE
P405: Store locked up.
P410: Protect from sunlight.
P402+P404: Store in a dry place. Store in a closed container.
P403+P235: Store in a well-ventilated place. Keep cool.
DISPOSAL
P501: If they can not be recycled, dispose of contents to an approved waste disposal plant and containers to
landfill (see Section 13 of this SDS).
Emergency Overview
Physical Description & Colour: Dark brown liquid.

---

Product Name: PCT Reactor Surfactant 700
Page: 2 of 5
This version issued: October, 2021
SAFETY DATA SHEET
Issued by: PCT Holdings Pty Ltd Phone:  (all hours)
Poisons Information Centre: 13 1126 from anywhere in Australia, (0800 764 766 in New Zealand)
Odour: Pungent, vinegar-like odour.
Major Health Hazards: causes serious eye irritation.

Section 3 - Composition/Information on Ingredients
| Ingredients | CAS No | Conc,% | TWA (mg/m³) | STEL (mg/m³) |
| :--- | :--- | :--- | :--- | :--- |
| Propionic acid | 79-09-4 | 350g/L | 30 | not set |
| Soyal Phospholipids | 8002-43-5 | 350g/L | not set | not set |
| Surfactants | secret | to 100 | not set | not set |

This is a commercial product whose exact ratio of components may vary slightly. Minor quantities of other non
hazardous ingredients are also possible.
The SWA TWA exposure value is the average airborne concentration of a particular substance when calculated over a normal 8 hour working day
for a 5 day working week. The STEL (Short Term Exposure Limit) is an exposure value that may be equalled (but should not be exceeded) for no
longer than 15 minutes and should not be repeated more than 4 times per day. There should be at least 60 minutes between successive exposures
at the STEL. The term "peak "is used when the TWA limit, because of the rapid action of the substance, should never be exceeded, even briefly.

Section 4 - First Aid Measures
General Information:
You should call The Poisons Information Centre if you feel that you may have been poisoned, burned or irritated by
this product. The number is 13 1126 from anywhere in Australia (0800 764 766 in New Zealand) and is available at all
times. Have this SDS with you when you call.
Inhalation: No first aid measures normally required. However, if inhalation has occurred, and irritation has
developed, remove to fresh air and observe until recovered. If irritation becomes painful or persists more than about
30 minutes, seek medical advice.
Skin Contact: Wash gently and thoroughly with water (use non-abrasive soap if necessary) for 10 minutes or until
chemical is removed. If irritation persists, repeat flushing and obtain medical advice.
Eye Contact: Immediately flush the contaminated eye(s) with lukewarm, gently flowing water for 15 minutes or until
the product is removed, while holding the eyelid(s) open. Take care not to rinse contaminated water into the
unaffected eye or onto the face. Obtain medical attention immediately. Take special care if exposed person is wearing
contact lenses.
Ingestion: If swallowed, do NOT induce vomiting. Wash mouth with water and contact a Poisons Information
Centre, or call a doctor.

Section 5 - Fire Fighting Measures
Fire and Explosion Hazards: The major hazard in fires is usually inhalation of heated and toxic or oxygen
deficient (or both), fire gases. There is no risk of an explosion from this product under normal circumstances if it is
involved in a fire. Violent steam generation or eruption may occur upon application of direct water stream on hot
liquids.
Fire decomposition products from this product are likely to be irritating if inhaled.
Extinguishing Media: Not combustible. Use extinguishing media suited to burning materials.
Fire Fighting: If a significant quantity of this product is involved in a fire, call the fire brigade. Cool closed,
undamaged containers exposed to fire with water spray.
Flash point: Does not burn.
Upper Flammability Limit: Does not burn.
Lower Flammability Limit: Does not burn.
Autoignition temperature: Not applicable - does not burn.
Flammability Class: Does not burn.

Section 6 - Accidental Release Measures
Accidental release: In the event of a major spill, prevent spillage from entering drains or water courses. Wear full
protective chemically resistant clothing including eye/face protection, gauntlets and self contained breathing
apparatus. See below under Personal Protection regarding Australian Standards relating to personal protective
equipment. No special recommendations for clothing materials. Eye/face protective equipment should comprise as a
minimum, protective goggles. If there is a significant chance that vapours or mists are likely to build up in the cleanup
area, we recommend that you use a respirator. Usually, no respirator is necessary when using this product. However,
if you have any doubts consult the Australian Standard mentioned below (section 8). Otherwise, not normally
necessary.
Stop leak if safe to do so, and contain spill. Absorb onto sand, vermiculite or other suitable absorbent material. If spill
is too large or if absorbent material is not available, try to create a dike to stop material spreading or going into drains

---

Product Name: PCT Reactor Surfactant 700
Page: 3 of 5
This version issued: October, 2021
SAFETY DATA SHEET
Issued by: PCT Holdings Pty Ltd Phone:  (all hours)
Poisons Information Centre: 13 1126 from anywhere in Australia, (0800 764 766 in New Zealand)
or waterways. Sweep up and shovel or collect recoverable product into labelled containers for recycling or salvage,
and dispose of promptly. Recycle containers wherever possible after careful cleaning. After spills, wash area
preventing runoff from entering drains. If a significant quantity of material enters drains, advise emergency services.
Contaminated area may be neutralised by washing with weak or dilute alkali. Baking soda, washing soda and
limestone are suitable. This material may be suitable for approved landfill. Ensure legality of disposal by consulting
regulations prior to disposal. Thoroughly launder protective clothing before storage or re-use. Advise laundry of nature
of contamination when sending contaminated clothing to laundry.

Section 7 - Handling and Storage
Handling: Keep exposure to this product to a minimum, and minimise the quantities kept in work areas. Check
Section 8 of this SDS for details of personal protective measures, and make sure that those measures are followed.
The measures detailed below under "Storage" should be followed during handling in order to minimise risks to
persons using the product in the workplace. Also, avoid contact or contamination of product with incompatible
materials listed in Section 10.
Storage: This product is a Scheduled Poison. Observe all relevant regulations regarding sale, transport and storage
of this schedule of poison. Protect this product from light. Store in the closed original container in a dry, cool, well
ventilated area out of direct sunlight. Make sure that the product does not come into contact with substances listed
under "Incompatibilities" in Section 10. Some liquid preparations settle or separate on standing and may require
stirring before use. Check packaging - there may be further storage instructions on the label.

Section 8 - Exposure Controls and Personal Protection
The following Australian Standards will provide general advice regarding safety clothing and equipment:
Respiratory equipment: AS/NZS 1715, Protective Gloves: AS 2161, Occupational Protective Clothing: AS/NZS 4501
set 2008, Industrial Eye Protection: AS1336 and AS/NZS 1337, Occupational Protective Footwear: AS/NZS2210.
SWA Exposure Limits TWA (mg/m³) STEL (mg/m³)
Propionic acid 30 not set
No special equipment is usually needed when occasionally handling small quantities. The following instructions are
for bulk handling or where regular exposure in an occupational setting occurs without proper containment systems.
Ventilation: This product should only be used in a well ventilated area. If natural ventilation is inadequate, use of
a fan is suggested.
Eye Protection: Protective glasses or goggles must be worn when this product is being used. Failure to protect
your eyes may lead to severe harm to them or to general health. Emergency eye wash facilities must also be
available in an area close to where this product is being used.
Skin Protection: You should avoid contact even with mild skin irritants. Therefore you should wear suitable
impervious elbow-length gloves and facial protection when handling this product. See below for suitable material
types.
Protective Material Types: We suggest that protective clothing be made from the following materials: PVC.
Respirator: Usually, no respirator is necessary when using this product. However, if you have any doubts consult
the Australian Standard mentioned above. Otherwise, not normally necessary.
Safety deluge showers should, if practical, be provided near to where this product is being handled commercially.

Section 9 - Physical and Chemical Properties:
Physical Description & colour: Dark brown liquid.
Odour: Pungent, vinegar-like odour.
Boiling Point: Not available.
Freezing/Melting Point: No specific data. Liquid at normal temperatures.
Volatiles: No data.
Vapour Pressure: 0.5kPa at 25°C (propionic acid)
Vapour Density: No data.
Specific Gravity: 1.035
Water Solubility: Dispersible.
pH: 3.6 (1% in water)
Volatility: No data.
Odour Threshold: No data.
Evaporation Rate: No data.
Coeff Oil/water Distribution: Kow Log P is 0.25 (propionic acid) (log P octanol/water)
Autoignition temp: Not applicable - does not burn.

---

Product Name: PCT Reactor Surfactant 700
Page: 4 of 5
This version issued: October, 2021
SAFETY DATA SHEET
Issued by: PCT Holdings Pty Ltd Phone:  (all hours)
Poisons Information Centre: 13 1126 from anywhere in Australia, (0800 764 766 in New Zealand)

Section 10 - Stability and Reactivity
Reactivity: This product is unlikely to react or decompose under normal storage conditions. However, if you have
any doubts, contact the supplier for advice on shelf life properties.
Conditions to Avoid: Protect this product from light. Store in the closed original container in a dry, cool, well-
ventilated area out of direct sunlight.
Incompatibilities: bases, oxidising agents.
Fire Decomposition: Combustion forms carbon dioxide, and if incomplete, carbon monoxide and possibly smoke.
Water is also formed. May form oxides of phosphorus and other phosphorus compounds. Carbon monoxide poisoning
produces headache, weakness, nausea, dizziness, confusion, dimness of vision, disturbance of judgment, and
unconsciousness followed by coma and death.
Polymerisation: This product will not undergo polymerisation reactions.

Section 11 - Toxicological Information
Local Effects:
Target Organs: There is no data to hand indicating any particular target organs.
Acute Toxicity - Oral LD50 (rat) >5000 mg/kg for a similar formulation
Dermal LD50 (rabbit) >5000 mg/kg for a similar formulation
Inhalation LC50 (rat) (4hr) >6.04 mg/l for a similar formulation

Classification of Hazardous Ingredients
Ingredient
Propionic Acid
• Acute toxicity – category 3
• Acute toxicity – category 4
• Skin corrosion – category 1B
• Specific target organ toxicity (single exposure) – category 3

Potential Health Effects
Inhalation:
Short Term Exposure: Inhalation of vapours or mists of this material will result in irritation of the nose, throat and
lungs. Symptoms may include nasal irritation, sore throat, coughing, hoarseness and, in extreme exposures,
breathing difficulties.
Long Term Exposure: No data for health effects associated with long term inhalation.
Skin Contact:
Short Term Exposure: Available data indicates that this product is not harmful. It should present no hazards in
normal use. However product is believed to be mildly irritating, but is unlikely to cause anything more than mild
transient discomfort.
Long Term Exposure: No data for health effects associated with long term skin exposure.
Eye Contact:
Short Term Exposure: This product is a severe eye irritant. Symptoms may include stinging and reddening of eyes
and watering which may become copious. Other symptoms such as swelling of eyelids and blurred vision may also
become evident. If exposure is brief, symptoms should disappear once exposure has ceased. However, lengthy
exposure or delayed treatment is likely to cause permanent damage.
Long Term Exposure: No data for health effects associated with long term eye exposure.
Ingestion:
Short Term Exposure: Significant oral exposure is considered to be unlikely. However, this product is an oral
irritant. Symptoms may include pain and reddening of skin in mouth and throat. Other symptoms may also become
evident, and may last after exposure has ceased.
Long Term Exposure: No data for health effects associated with long term ingestion.
Carcinogen Status:
SWA: No significant ingredient is classified as carcinogenic by SWA.
NTP: No significant ingredient is classified as carcinogenic by NTP.
IARC: No significant ingredient is classified as carcinogenic by IARC.

---

Product Name: PCT Reactor Surfactant 700
Page: 5 of 5
This version issued: October, 2021
SAFETY DATA SHEET
Issued by: PCT Holdings Pty Ltd Phone:  (all hours)
Poisons Information Centre: 13 1126 from anywhere in Australia, (0800 764 766 in New Zealand)

Section 12 - Ecological Information
This product is biodegradable. It will not accumulate in the soil or water or cause long term problems.
For Propionic acid:
Fish: LC50 bluegill sunfish: 210mg/L LC50 rainbow trout: 130mg/L
Daphnia: EC50 170mg/L

Section 13 - Disposal Considerations
Disposal: This product may be recycled if unused, or if it has not been contaminated so as to make it unsuitable for
its intended use. If it has been contaminated, it may be possible to reclaim the product by filtration, distillation or some
other means. If neither of these options is suitable in-house, consider controlled incineration, or contact a specialist
waste disposal company.

Section 14 - Transport Information
UN Number: This product is not classified as a Dangerous Good by ADG, IATA or IMDG/IMSBC criteria. No special
transport conditions are necessary unless required by other regulations.

Section 15 - Regulatory Information
AICS: All of the significant ingredients in this formulation are compliant with NICNAS regulations.
The following ingredient: Propionic acid, is mentioned in the SUSMP.

Section 16 - Other Information
This SDS contains only safety-related information. For other data see product literature.
Acronyms:
ADG Code Australian Code for the Transport of Dangerous Goods by Road and Rail (7th edition)
AICS Australian Inventory of Chemical Substances
SWA Safe Work Australia, formerly ASCC and NOHSC
CAS number Chemical Abstracts Service Registry Number
Hazchem Code Emergency action code of numbers and letters that provide information to emergency
services especially firefighters
IARC International Agency for Research on Cancer
NOS Not otherwise specified
NTP National Toxicology Program (USA)
R-Phrase Risk Phrase
SUSMP Standard for the Uniform Scheduling of Medicines & Poisons
UN Number United Nations Number
THIS SDS SUMMARISES OUR BEST KNOWLEDGE OF THE HEALTH AND SAFETY HAZARD INFORMATION OF THE PRODUCT AND HOW
TO SAFELY HANDLE AND USE THE PRODUCT IN THE WORKPLACE. EACH USER MUST REVIEW THIS SDS IN THE CONTEXT OF HOW
THE PRODUCT WILL BE HANDLED AND USED IN THE WORKPLACE.
IF CLARIFICATION OR FURTHER INFORMATION IS NEEDED TO ENSURE THAT AN APPROPRIATE RISK ASSESSMENT CAN BE MADE,
THE USER SHOULD CONTACT THIS COMPANY SO WE CAN ATTEMPT TO OBTAIN ADDITIONAL INFORMATION FROM OUR SUPPLIERS
OUR RESPONSIBILITY FOR PRODUCTS SOLD IS SUBJECT TO OUR STANDARD TERMS AND CONDITIONS, A COPY OF WHICH IS SENT
TO OUR CUSTOMERS AND IS ALSO AVAILABLE ON REQUEST.
Please read all labels carefully before using product.
This SDS is prepared in accord with the SWA document “Preparation of Safety Data Sheets for Hazardous
Chemicals - Code of Practice” (Feb 2016)
Copyright © Kilford & Kilford Pty Ltd, October, 2021.